De grootste kennisbank van het HBO

Inspiratie op jouw vakgebied

Vrij toegankelijk

Terug naar zoekresultatenDeel deze publicatie

Measurement of range-of-motion in infants with indications of upper cervical dysfunction using the Flexion-Rotation-Test and Lateral-Flexion-Test: a blinded inter-rater reliability study in a clinical practice setting.

Measurement of range-of-motion in infants with indications of upper cervical dysfunction using the Flexion-Rotation-Test and Lateral-Flexion-Test: a blinded inter-rater reliability study in a clinical practice setting.

Samenvatting

Background: In infants with indications of upper cervical dysfunction, the Flexion-Rotation-Test and Lateral-Flexion-Test are used to indicate reduced upper cervical range-of-motion (ROM). In infants, the inter-rater reliability of these tests is unknown. Objective: To assess the inter-rater reliability of subjectively and objectively measured ROM by using the Flexion-Rotation-Test and Lateral-Flexion-Test. Methods: 36 infants (<6 months) and three manual therapists participated in this cross-sectional observational study. Pairs of two manual therapists independently assessed infants' upper cervical ROM using the Flexion-Rotation-Test and Lateral-Flexion-Test, blinded for each other's outcomes. Two inertial motion sensors objectively measured cervical ROM. Inter-rater reliability was determined between each pair of manual therapists. For subjective outcomes, Cohen's kappa (ĸ) and the proportion of agreement (Pra) were calculated. For objectively measured ROM, Bland Altman plots were conducted and Limits of Agreement and Intraclass Correlation Coefficients (ICC) were calculated. Results: The inter-rater reliability of the Flexion-Rotation-Test and Lateral-Flexion-Test for subjective (ĸ: 0.077-0.727; Pra: 0.46-0.86) and objective outcomes (ICC: 0.019-0.496) varied between pairs of manual therapists. Conclusion: Assessed ROM largely depends on the performance of the assessment and its interpretation by manual therapists, leading to high variation in outcomes. Therefore, the Flexion-Rotation-Test and Lateral-Flexion-Test cannot be used solely as a reliable outcome measure in clinical practice and research context.

Toon meer
OrganisatieHAN University of Applied Sciences
AfdelingAcademie Paramedische Studies
Lectoraten
LectoraatWerkzame Factoren in Fysiotherapie en Paramedisch Handelen
Gepubliceerd inJournal of Manual & Manipulative Therapy Journal of Manual & Manipulative Therapy, Vol. 29, Uitgave: 1, Pagina's: 40-50
Jaar2021
TypeArtikel
DOI10.1080/10669817.2020.1746896
TaalOnbekend

Op de HBO Kennisbank vind je publicaties van 26 hogescholen

De grootste kennisbank van het HBO

Inspiratie op jouw vakgebied

Vrij toegankelijk